Strany 1 - HYDROLOGICAL SERVICES

HYDROLOGICAL SERVICESDL3 100-01 IMPIssue 2: 15/11/2005RAIN/RIVER DATA LOGGERMODEL RRDL3-IMPERIALOPERATION MANUALHYDROLOGICAL SERVICES Pty Ltd48-50 Scr

Strany 2 - Table of Contents

HYDROLOGICAL SERVICESDL3 100-010 IMPIssue 2: 15/11/20053.2Setup and Configuring the LoggerOnce the RRDL-3 logger has been connected to a computer, the

Strany 3 - APPENDIX A

HYDROLOGICAL SERVICESDL3 100-011 IMPIssue 2: 15/11/2005of the specific TBRG used as well as the number of tips that defines one rainfall event - thisd

Strany 4 - 1.Introduction

HYDROLOGICAL SERVICESDL3 100-012 IMPIssue 2: 15/11/2005is powered before a measurement is made. The "River Increment" (RVI) parameter define

Strany 5 - 2.Product Overview

HYDROLOGICAL SERVICESDL3 100-013 IMPIssue 2: 15/11/20054. Operation4.1 Commands / SyntaxEach of the logger commands that follow are described in detai

Strany 6 - 3.Installation

HYDROLOGICAL SERVICESDL3 100-014 IMPIssue 2: 15/11/20054.1.2 Alarms (AL, CLA, DUA, RALx, RVALx)Alarm messages are generated when rainfall and river he

Strany 7 - 3.1.2 River Sensor

HYDROLOGICAL SERVICESDL3 100-015 IMPIssue 2: 15/11/2005Rainfall (mm) Daily Accumulated Rainfall Chart0900 0900 09002100 210002550Time (hours)Trigger A

Strany 8 - 3.1.3 Communications

HYDROLOGICAL SERVICESDL3 100-016 IMPIssue 2: 15/11/2005RainfallTimeIntervalRainfallamountIntervalRainfallamountTrigger Alarm messagerestart alarmcheck

Strany 9 - 3.1.4 DIP Switches

HYDROLOGICAL SERVICESDL3 100-017 IMPIssue 2: 15/11/2005River HeightTimeRvAl1RvAl2Trigger Alarm RvAl1Trigger Alarm RvAl2HydrographRiver Alarm 1 and Riv

Strany 10 - 3.2.2 System Time/Date

HYDROLOGICAL SERVICESDL3 100-018 IMPIssue 2: 15/11/2005River HeightTimeIntervalchangein RvHthresholdRvAl3 = change in River Height / Interval /above t

Strany 11

HYDROLOGICAL SERVICESDL3 100-019 IMPIssue 2: 15/11/20054.1.3 Battery Voltage (BV)The RRDL-3 logger battery voltage is measured and displayed when the

Strany 12 - 3.2.6 Communications

HYDROLOGICAL SERVICESDL3 100-02 IMPIssue 2: 15/11/2005Table of ContentsPage1. Introduction DL3 100-04 IMP2. Product Overview DL3 100-05 IMP3. Installa

Strany 13 - 4. Operation

HYDROLOGICAL SERVICESDL3 100-020 IMPIssue 2: 15/11/20055. A CLEAR sequence is performed again to get the modem back into a known state.6. If there is

Strany 14

HYDROLOGICAL SERVICESDL3 100-021 IMPIssue 2: 15/11/20054.1.6 Communications (COM, SEND, EV, RE, RETRY)The communications of the RRDL-3 logger is set u

Strany 15

HYDROLOGICAL SERVICESDL3 100-022 IMPIssue 2: 15/11/2005As events occur they are transmitted on the serial port. A rain event is transmitted as a time,

Strany 16

HYDROLOGICAL SERVICESDL3 100-023 IMPIssue 2: 15/11/20054.1.7 Date/Time Parameters (D, T, TO)The logger date and time is maintained in a battery backed

Strany 17

HYDROLOGICAL SERVICESDL3 100-024 IMPIssue 2: 15/11/20054.1.8 Dump Log (DUR, CLR, DURV, CLRV, LOG)The loggers rain and river log data is stored in a co

Strany 18

HYDROLOGICAL SERVICESDL3 100-025 IMPIssue 2: 15/11/2005On-line helpCLR?Clear Rainfall Log: Totally erases the rainfall logSyntax: CLA<CR> (OK wh

Strany 19 - 4.1.4 Bye (BYE)

HYDROLOGICAL SERVICESDL3 100-026 IMPIssue 2: 15/11/2005the most recent data is always available. It is advisable that when changing the state of the M

Strany 20

HYDROLOGICAL SERVICESDL3 100-027 IMPIssue 2: 15/11/2005On-line HelpPASSWD?Password: Four character passwd to allow user accessto alter parameters or c

Strany 21

HYDROLOGICAL SERVICESDL3 100-028 IMPIssue 2: 15/11/20054.1.11 River Parameters Quadrature (RVCHID, RVI, RVHR)The "River Channel ID" (RVCHID)

Strany 22

HYDROLOGICAL SERVICESDL3 100-029 IMPIssue 2: 15/11/2005The analog 4-20mA pressure transducer that measures river depth connects to the RRDL-3 loggerth

Strany 23

HYDROLOGICAL SERVICESDL3 100-03 IMPIssue 2: 15/11/2005Table of Contents cont’dPage5. Specification DL3 100-38 IMP5.1. Hardware Specifications DL3 100-

Strany 24

HYDROLOGICAL SERVICESDL3 100-030 IMPIssue 2: 15/11/20054.1.13 Status (ST, COM, R, RV)4.1.13.1 The Status Window (ST)The Status Window returns a summar

Strany 25

HYDROLOGICAL SERVICESDL3 100-031 IMPIssue 2: 15/11/2005DOWE HAVE A LASTTREND BIAS ?Goto last River HeightEvent RecordISEVENT WITHININTERVAL ?Get Next

Strany 26

HYDROLOGICAL SERVICESDL3 100-032 IMPIssue 2: 15/11/2005Trigger 24 hour timerISRvH > RvHp ?RvHp=RvHRvHpT = Time @ nowRvHpD = Date @ nowNEXTEVENT ?Ti

Strany 27

HYDROLOGICAL SERVICESDL3 100-033 IMPIssue 2: 15/11/20054.1.13.3 The Rainfall Message (R)The following data format represents the standard rainfall mes

Strany 28

HYDROLOGICAL SERVICESDL3 100-034 IMPIssue 2: 15/11/20054.1.13.4 The River Height Message (RV)The following data format represents the standard river h

Strany 29

HYDROLOGICAL SERVICESDL3 100-035 IMPIssue 2: 15/11/20054.1.13.5 Water Level (WL)The "Water Level" command (WL) displays the present water le

Strany 30

HYDROLOGICAL SERVICESDL3 100-036 IMPIssue 2: 15/11/2005Field Par. Parameter DefinitionStation Set-upHeaderMELB0012345HS00010.01Site Name, variable len

Strany 31

HYDROLOGICAL SERVICESDL3 100-037 IMPIssue 2: 15/11/2005StationSet-upHeader MELB 0567890 XX0001 150< crlf >Logger Start Header 09:35:23 4/24/94 2

Strany 32

HYDROLOGICAL SERVICESDL3 100-038 IMPIssue 2: 15/11/20055. Specification5.1 Hardware Specification5.1.1. GeneralMicroprocessor Intel 80C196Program Memo

Strany 33

HYDROLOGICAL SERVICESDL3 100-039 IMPIssue 2: 15/11/2005Power Supply 6V to 14V DC unregulated.75mA operating mode 200uA sleep mode.Transient Protection

Strany 34

HYDROLOGICAL SERVICESDL3 100-04 IMPIssue 2: 15/11/2005LAN / WANPORTABLE PCCommunicationInterfaceOR ORRRDL-3 LoggerLogger returnedTelephone, Radio, Sat

Strany 35 - 4.2 Data Output Format

HYDROLOGICAL SERVICESDL3 100-040 IMPIssue 2: 15/11/20055.1.4 Communications InterfaceThe communications interface is very powerful and flexible, allow

Strany 36 - 4.2.2 River Height Record

HYDROLOGICAL SERVICESDL3 100-041 IMPIssue 2: 15/11/2005average current drain = [(1.7% X 155 mA )+ (98.3% x 200 uA)] 100 = 2.83 mAcontinuousPower = 12

Strany 37

HYDROLOGICAL SERVICESDL3 100-042 IMPIssue 2: 15/11/2005an accuracy of better than 30 seconds per month with resolution to one second across anoperatin

Strany 38 - 5. Specification

HYDROLOGICAL SERVICESDL3 100-043 IMPIssue 2: 15/11/20056. Fault FindingThis fault finding guide should be used by the RRDL-3 user before they consult

Strany 39

HYDROLOGICAL SERVICESDL3 100-044 IMPIssue 2: 15/11/2005Check that you have the correct password, and you are entering it in the correct upper andlower

Strany 40 - 5.1.5 Watchdog

HYDROLOGICAL SERVICESDL3 100-045 IMPIssue 2: 15/11/2005When I dial through on a modem and wait more than 2 seconds I don’t get the "StatusWindow&

Strany 41 - 5.1.8 System Clock

HYDROLOGICAL SERVICESDL312 100-01 IMPIssue 2: 15/11/2005APPENDIX ARRDL-3 ‘COMLOG’COMMUNICATIONS SOFTWAREOPERATION MANUAL - IMPPART NO. DL312 1000HYDRO

Strany 42 - 5.1.10Start-up Indicator

HYDROLOGICAL SERVICESDL312 100-02 IMPIssue 2: 15/11/2005Table of ContentsPage1. Introduction DL312 100-03 IMP2. Hardware Connection DL312 100-03 IMP3.

Strany 43 - 6. Fault Finding

HYDROLOGICAL SERVICESDL312 100-03 IMPIssue 2: 15/11/20051. IntroductionThis software package has been specifically written to communicate to the Hydro

Strany 44

HYDROLOGICAL SERVICESDL312 100-04 IMPIssue 2: 15/11/2005Part No. Description PurposeDL307 Interrogation lead - DB9 Interrogation lead - logger to PC,

Strany 45

HYDROLOGICAL SERVICESDL3 100-05 IMPIssue 2: 15/11/2005LoggerTipping Bucket Rain GaugeLoggerExt. PowerRainfallRiver HeightRS232 Comm. Port.Direct or Mo

Strany 46 - PART NO. DL312 1000

HYDROLOGICAL SERVICESDL312 100-05 IMPIssue 2: 15/11/2005Use the F2 key to select your computer COM port and use F3, F4 and F5 keys to match theconfigu

Strany 47

HYDROLOGICAL SERVICESDL312 100-06 IMPIssue 2: 15/11/20056. Saving logger output in Spreadsheet formatThe Rain and River dump data from a logger may be

Strany 48 - 2. Hardware Connection

HYDROLOGICAL SERVICESDL3 100-06 IMPIssue 2: 15/11/2005TBRG Voltagefree contactBlack Connector Pin KBlack Connector Pin HRRDL-3 LoggerBlack Connector P

Strany 49 - 3. Software Installation

HYDROLOGICAL SERVICESDL3 100-07 IMPIssue 2: 15/11/2005Black Connector Pin KBlack Connector Pin JRRDL-3 LoggerBlack Connector Pin LQuadratureBvoltage f

Strany 50 - 5. Saving data to a file

HYDROLOGICAL SERVICESDL3 100-08 IMPIssue 2: 15/11/2005Black Connector Pin B4-20mA SenseBlack Connector Pin ASwitched +12VRRDL-3 LoggerBlack Connector

Strany 51 - 7. Exiting the program

HYDROLOGICAL SERVICESDL3 100-09 IMPIssue 2: 15/11/2005Red Connector Pin CCarrier Detect (CD)Red Connector Pin ATx DataRRDL-3 LoggerRed Connector Pin E

Komentáře k této Příručce

Žádné komentáře

Aquatic Cucina manuali utente

Partendo da M

Cliccare su un alfabeto di seguito per far scorrere la lista completa dei modellif models starting with that letter

Modelli Tipo di Documento
MILLENNIUM 10 AI10MIL8248
Manuale Utente   Aquatic MILLENNIUM 10 AI10MIL8248 User Manual, 1 pagine
MILLENNIUM 7 AI7mIl7257
Manuale Utente   Aquatic MILLENNIUM 7 AI7mIl7257 User Manual, 1 pagine
MILLENNIUM 8 AI8mIl7272
Manuale Utente   Aquatic MILLENNIUM 8 AI8mIl7272 User Manual, 1 pagine
MILLENNIUM 9 AI9mIl7700
Manuale Utente   Aquatic MILLENNIUM 9 AI9mIl7700 User Manual, 1 pagine